測量指標(biāo) 電導(dǎo)率(EC) 總固體溶解度(TDS) 測量范圍 (20℃或25℃溫度補(bǔ)償) 0.00 to 29.99μS/cm or 30.0 to 299.9μS/cm 300 to 2999μS/cm or 3.00 to 29.99mS/cm 30.0 to 200.0mS/cm Up to 500.0mS/cm(不進(jìn)行溫度補(bǔ)償時(shí)測量電導(dǎo)值) 0.00 to 14.99ppm or 15.0 to 149.9ppm 150 to 1499ppm or 1.50 to 14.99g/l 15.0 to 100.0g/l Up to 400.0g/l(不進(jìn)行溫度補(bǔ)償時(shí)測量TDS值) 解 析 度 0.01μS/cm(0.00 to 29.99μS/cm) 0.1μS/cm(30.0 to 299.9μS/cm) 1μS/cm(300 to 2999μS/cm) 0.01ms /cm(3.00 to 29.99ms/cm) 0.1mS/cm(30.0mS/cm以上) 0.01ppm(0.00 to 14.99ppm) 0.1ppm(15.0 to 149.9ppm) 1ppm(150 to 1499ppm) 0.01g/l(1.50 to 14.99g/l) 0.1g/l(15.0g/l以上) 精 確 度 ±1%讀數(shù)±(0.05μS/cm測量值) ±1%讀數(shù)±(0.03ppm測量值) 校 正 點(diǎn) 內(nèi)設(shè)六個(gè)校正點(diǎn)自動(dòng)識(shí)別 電導(dǎo)校正同時(shí)TDS自動(dòng)識(shí)別校正 轉(zhuǎn)換因子 __ 0.40 to 0.80(出廠默認(rèn)值0.50) 溫度補(bǔ)償 自動(dòng)或手動(dòng)補(bǔ)償0 to 60℃ 自動(dòng)或手動(dòng)補(bǔ)償0 to 60℃ 溫度補(bǔ)償常數(shù) 0.00 to 6.00%/℃(出廠默認(rèn)值1.90%/℃) 測量指標(biāo) 鹽度(NaCl) 溫度(℃) 測量范圍 0.0 to 400.0% 0.0 to 60℃ 解 析 度 0.10% 0.1℃ 精 度 ±1%讀數(shù) ±0.4℃ 校 正 點(diǎn) 單點(diǎn)自動(dòng)識(shí)別校正(推薦校正液HI7037) 2個(gè)溫度校正點(diǎn)0℃和50℃(調(diào)整間隔±1℃) 配套電極 HI76310具有ATC功能四環(huán)高性能電導(dǎo)電極(電導(dǎo)常數(shù)K=1) 數(shù)據(jù)接口 RS232 配套電源 HI710006專用220V/12VDC電源
適用環(huán)境 0.0 to 50.0℃ 95%RH 尺寸/重量 240×182×74mm / 1200g